Published March 21, 1996 | Version v1
Journal article

Investigation of the radiation damage of GaAs detectors by neutrons and photons

  • 1. Technische Hochschule Aachen (Germany). 1. Physikalisches Inst.

Description

Surface barrier particle detectors, processed in Aachen using SI GaAs from several manufacturers, have been irradiated with neutrons (peak energy similar 1 MeV) up to fluences of 4.0.1014 n/cm2 and with photons from a 60Co source with a dose of 100 Mrad. All detectors work well after the irradiation. Detectors biased with 200 V during the neutron irradiation show no significant difference from those not biased. After irradiation with 4.0.1014 n/cm2 the leakage currents at 200 V are a factor of 4 greater than those before irradiation. At the highest radiation level the signal for minimum ionizing particles corresponds to 7200 electrons (at 200 V bias voltage) independent of peaking times between 40 ns and 2.2 μs. The signals for α-particles (2.2 μs peaking time, 200 V bias voltage) are about 20% of those before irradiation. The exposure to the 100 Mrad photon dose caused little change of the detector performance. The leakage currents were even reduced by about 10%. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
372
Journal Issue
1-2
Journal Page Range
p. 111-116.
ISSN
0168-9002
CODEN
NIMAER