Published August 1997 | Version v1
Journal article

Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients

  • 1. Department of Radiology, Hopital Michallon, CHU Grenoble BP 217, F-38 043 Grenoble Cedex 09 (France)
  • 2. GE Medical Systems, 283 rue de la Miniere, BP 34 F-78 533 Buc Cedex (France)
  • 3. TIMC-IMAG-UJF, URA CNRS D 1618, Institut Albert Bonniot, Domaine de la Merci, F-38 700 La Tronche (France)
  • 4. Department of Respiratory Disease, CHU Grenoble BP 217, F-38 043 Grenoble Cedex 09 (France)

Description

The purpose of this study was to determine the feasibility of using virtual bronchoscopy simulations to depict stenoses of the tracheobronchial tree. Virtual bronchoscopy simulations, based on ray casting, were applied to spiral-CT data sets of 29 patients presenting 41 stenoses of the central airways, proved with fiberoptic bronchoscopy. Simulations of the inner walls of the airways were of good quality in 27 of 29 patients. Airway stenoses were depicted in 39 of 41 cases. Evaluation of the length of stenoses and surrounding tissues required simultaneous display of multiplanar reformations. Virtual bronchoscopy provides a valuable road map for bronchoscopy, in an image format familiar to bronchoscopists. (orig.). With 4 figs., 2 tabs

Additional details

Publishing Information

Journal Title
European Radiology
Journal Volume
7
Journal Issue
6
Journal Page Range
p. 854-859.
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
28057037
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CHIRALITY; COMPUTERIZED TOMOGRAPHY; LUNGS; SIDE EFFECTS; SURVIVAL TIME; THERAPY; TRANSPLANTS
Descriptors DEC
BODY; MEDICINE; ORGANS; PARTICLE PROPERTIES; RESPIRATORY SYSTEM; TOMOGRAPHY