Published June 1991 | Version v1
Report

Effect of space exposure on pyroelectric infrared detectors

Description

Twenty pyroelectric type infrared detectors were flown onboard the Long Duration Exposure Facility (LDEF). The detector chips were of three different pyroelectric materials: lithium-tantalate, strontium-barium-niobate, and triglycine-sulfide. The experiment was passive; no measurements were taken during the flight. Performance of the detectors was measured before and after flight. Postflight measurements revealed that detectors made of lithium-tantalate and strontium-barium-niobate suffered no measureable loss in performance. Detectors made of triglycine-sulfide suffered complete loss of performance, but so did the control samples of the same material. Repoling of the triglycine-sulfide failed to revive the detectors

Additional details

Publishing Information

Imprint Title
First LDEF Post-Retrieval Symposium abstracts
Imprint Pagination
vp.
Journal Page Range
p. 107.
Report number
N--91-24972

Conference

Title
1. Long Duration Exposure Facility (LDEF) post-retrieval symposium.
Dates
3-8 Jun 1991.
Place
Kissimmee, FL (USA).

Optional Information

Notes
Imprint:Abstract Only.
Secondary number(s)
NASA-CP--10072; NAS--1.55:10072; CONF-9106256--.