Published January 2005 | Version v1
Journal article

Gamma dose rate profiles in fuelling machine vaults before and after PHT system decontamination in MAPS-1 for EMCCR campaign

  • 1. Health Physics Unit, Madras Atomic Power Station, Kalpakkam (India)
  • 2. Health Physics Unit, Kudankulam Nuclear Power Project, Kudankulam (India)
  • 3. Health Physics Unit, KAPS, Health Physics Div., Bhabha Atomic Research Centre (India)

Description

Fuelling machine vault, an area on either side of the Reactor core, is the center stage for the En masse coolant channel replacement (EMCCR) campaign, a dose intensive mega exercise. During the EMCCR of Unit-2 (2002-2003), the collective dose consumption in FM vault was nearly 90 percent. In August 2003, Unit-1 was shut down for taking up EMCCR. Prior to the commencement of this campaign, the PHT system was decontaminated by Dilute Chemical Decontamination technique (DCD). To study the impact in FM vault, gamma dose rate mapping was carried out extensively before and after DCD. Critical observations of this study which had a bearing on the ALARA decisions during the EMCCR are highlighted in this paper. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
28
Journal Issue
1-4
Journal Page Range
p. 94-96
CODEN
RPREFM

Conference

Title
27. IARP national conference on occupational and environmental radiation protection
Acronym
IARPNC 2005
Dates
23-25 Nov 2005
Place
Mumbai (India)

Optional Information

Notes
2 refs., 4 figs.