Published November 1982 | Version v1
Journal article

Results of the 2nd regular inspection of Unit 6 in the Fukushima No. 1 Nuclear Power Station

Description

The 2nd regular inspection of Unit 6 in the Fukushima No. 1 Nuclear Power Station in fiscal 1981 was carried out in the period of December, 1981, to April, 1982. Inspection was made on the reactor proper, reactor cooling system, fuel facility, radiation control, etc. By the examinations of external appearance, leakage, performance, etc., abnormality was not observed. The personnel radiation exposure doses during the inspection were all below the permissible levels. Improvement and other works made during the inspection were as follows: In the isolation valves in the control system for inflammable gas concentration, to improve their maintainability, the existing valves were replaced by domestically made ones of the same function. (Mori, K.)

Additional details

Publishing Information

Journal Title
Genshiryoku Anzen Iinkai Geppo
Journal Issue
no.47
Series
Genshiryoku Anzen Iinkai Geppo.