Published February 1, 1985 | Version v1
Journal article

Biosynthetic labeling with 32P: radiation damage to mammalian cells

  • 1. Ludwig Institute for Cancer Research, Victoria, Australia

Description

Theoretical calculations showed that biosynthetic radiolabeling of cells using typical concentrations of 32P (1 mCi/ml) resulted in high radiation doses (200-500 rad/h) being absorbed by the cells. Subsequent investigations with a mouse myelomonocytic leukemia cell line (WEHI-3B(D+)) showed significant loss of replicative ability during brief (less than 1 h) exposures to 1 mCi/ml of 32P. Complete loss of cell replicative ability was found with isotopic doses less than 100 rad. Experiments employing a less radiosensitive pre-B-cell line (18.81) revealed that significant loss of viability occurred during incubation with 32P under identical conditions to those employed for the WEHI-3B(D+) cell line. Control experiments utilizing decayed batches of 32P and physical separation of the isotope solution from the cells confirmed that the cytotoxicity was caused by radiation emission rather than the presence of toxic components in the isotopic solution. The radiation doses absorbed by cells biosynthetically labeled with 59Fe, 33P, 35S, and 14C were calculated. Although significant levels of radiation can be absorbed 32P was considerably more radiotoxic than the other isotopes. The results of calculations indicated that the judicious choice of container geometry could reduce the absorbed radiation dose from 32P solutions

Additional details

Publishing Information

Journal Title
Anal. Biochem.
Journal Issue
no.2
Series
Anal. Biochem.
ISSN
0003-2697
CODEN
ANBCA