Published April 2001
| Version v1
Report
Open
Risk assessment of accident of uncontrolled boron dilution at shutdown condition for PWR
- 1. China Inst. of Atomic of Energy, Beijing (China)
Description
Taking Guangdong Daya Bay Nuclear Power Station for reference plant, the potential accident initiators of uncontrolled boron dilution at shutdown condition for pressurized water reactor is analyzed and classified systematically. Based upon French NPPs operating experience over 750 reactor-years, the PSA method is adopted to evaluate the risk related to such accident. Finally, according to the estimated result some appropriate measures and recommendations to reduce the corresponding risk are proposed
Availability note (English)
Available from INIS in electronic formFiles
33017084.pdf
Files
(1.7 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:c10ad58c4b242b27d6070728487db9aa
|
1.7 MB | Preview Download |
Additional details
Publishing Information
- ISBN
- 7-89999-317-2
- Imprint Pagination
- 15 p.
- Journal Issue
- CNIC/CD/2001-1
- Series
- China Nuclear Science and Technology Report
- Report number
- CNIC--01455
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 33017084
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- BORON; DAYA BAY REACTOR; DILUTION; NUCLEAR POWER PLANTS; REACTOR ACCIDENTS; REACTOR SHUTDOWN; RISK ASSESSMENT
- Descriptors DEC
- ACCIDENTS; ELEMENTS; ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; SEMIMETALS; SHUTDOWN; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Data in PDF format: Acrobat Reader for Windows 9x; this record replaces RN: 32036044
- Secondary number(s)
- IAE--0197