Technetium-99m l, l-ethylenedicysteine clearance and correlation with iodine-125 orthoiodohippurate for the determination of effective renal plasma flow
Creators
- 1. Centre of Nuclear Medicine, University of Louvain (UCL), Brussels (Belgium)
- 2. Laboratory of Radiopharmaceutical Chemistry I.F.W, K.U. Leuven (Belgium)
- 3. Department of Renal Transplantation, University of Louvain (UCL), Brussels (Belgium)
Description
Technetium-99m l, l-ethylenedicysteine (99mTc-l, l-EC) is a new renal tubular tracer that allows the determination of the effective renal plasma flow (ERPF). The aim of this study was to derive simplified methods for the estimation of 99mTc-l, l-EC clearance using one or two plasma samples after bolus injection. Fifty-nine multiple plasma dual-tracer samples (nine samples from 5 to 120 min after injection) were obtained after injection of kit-formulated 99mTc-l, l-EC and iodine-125 orthoiodohippurate (OIH). The studies were performed in 25 stable and 24 unstable transplant recipients, in five patients with renal insufficiency (four on chronic haemodialysis) and in five normal volunteers. This allowed a wide range of renal function values to be covered, with ERPF (estimated by OIH clearance) ranging from 25.4 to 604.0 ml/min. The reference 99mTc-l, l-EC clearance, as calculated from the multisample model, could be estimated from two samples at 15 and 90 min with an error of 11.3 ml/min and from one sample at 90 min with an error of 17.8 ml/min. Using appropriate linear regression analysis, ERPF could be estimated by the two- and one-sample 99mTc-l, l-EC clearance with an error of 24.2 and 22.8 ml/min, respectively. In conclusion, 99mTc-l, l-EC clearance can be accurately estimated by simplified one- or two-sample methods. Moreover, these methods can be used to estimate ERPF with an error that remains acceptable for clinical purposes. (orig.). With 4 figs., 11 tabs
Additional details
Publishing Information
- Journal Title
- European Journal of Nuclear Medicine
- Journal Volume
- 23
- Journal Issue
- 4
- Journal Page Range
- p. 365-370.
- ISSN
- 0340-6997
- CODEN
- EJNMD9
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 27059570
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; BIOLOGICAL FUNCTIONS; CYSTEINE; DIAGNOSIS; DYNAMIC FUNCTION STUDIES; KIDNEYS; MAN; PATIENTS; RADIOPHARMACEUTICALS; RENAL CLEARANCE; SAMPLING; SCINTISCANNING; TECHNETIUM COMPLEXES; TECHNETIUM 99; TRANSPLANTS
- Descriptors DEC
- AMINO ACIDS; ANIMALS; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CARBOXYLIC ACIDS; CLEARANCE; COMPLEXES; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DRUGS; EXCRETION; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; MAMMALS; MATERIALS; NUCLEI; ODD-EVEN NUCLEI; ORGANIC ACIDS; ORGANIC COMPOUNDS; ORGANIC SULFUR COMPOUNDS; ORGANS; PRIMATES; RADIOACTIVE MATERIALS; RADIOISOTOPE SCANNING; RADIOISOTOPES; TECHNETIUM ISOTOPES; THIOLS; TRANSITION ELEMENT COMPLEXES; VERTEBRATES; YEARS LIVING RADIOISOTOPES