Published May 1, 2008
| Version v1
Report
Alignment of the Near Detector scintillator modules using cosmic ray muons
Description
The authors describe the procedures and the results of the first alignment of the Near Detector. Using 15.5 million cosmic ray muon tracks, collected from October, 2004 through early january, 2005, they derive the effective transverse positions of the calorimeter scintillator modules. The residuals from straight line fits indicate that the current alignment has achieved better than 1 mm precision. They estimate the size of the remaining misalignment and using tracks recorded with a magnetic field test the effect of the magnetic field on the alignment
Availability note (English)
Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?tm-2411.pdf; PURL: https://www.osti.gov/servlets/purl/933210-ELGNP1/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 27 p.
- Report number
- FERMILAB-TM--2411-E
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 39084463
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- ACCURACY; ALIGNMENT; CALORIMETERS; MAGNETIC FIELDS; MUONS; PHOSPHORS
- Descriptors DEC
- ELEMENTARY PARTICLES; FERMIONS; LEPTONS; MEASURING INSTRUMENTS
Optional Information
- Contract/Grant/Project number
- AC02-76CH03000
- Notes
- 10.2172/933210
- Funding organization
- US Department of Energy (United States)