Published November 2005 | Version v1
Journal article

Development of cryogenic permanent magnet undulator

  • 1. RIKEN, Harima Institute, SPring-8, Sayo, Hyogo (Japan)
  • 2. Japan Synchrotron Radiation Research Inst., SPring-8, Sayo, Hyogo (JP)
  • 3. Univ. of Hyogo, Kamigori, Hyogo (JP)

Description

A short period undulator increases not only the photon energy of undulator radiation, but also the brilliance due to its increased number of undulator periods. As a result, brilliant undulator radiation becomes available in the photon energy range, which is currently covered by wigglers. In order to develop a short period undulator, high performance magnets are indispensable and superconductive undulators have been actively investigated in recent years. In this paper, however, we propose a new approach, so called a cryogenic permanent magnet undulator using NdFeB magnets at the temperatures around 150 K. The current status of this cryogenic permanent magnet undulator development at SPring-8 is presented including the results of the magnetic field measurements on a prototype undulator. (author)

Additional details

Publishing Information

Journal Title
Hoshako
Journal Volume
18
Journal Issue
6
Journal Page Range
p. 356-362
ISSN
0914-9287

Optional Information

Notes
19 refs., 9 figs., 1 tab.