Published March 2013
| Version v1
Journal article
Character of backlight imaging based on spherically bent crystal
Creators
- 1. Research Center of Laser Fusion, CAEP, Mianyang (China)
Description
By analyzing the monochromatic X-ray backlighting system with spherically bent crystal, the expressions for the spatial resolution and the spectral resolution of this system are deduced, and the relationship between these key performance parameters and the design parameters of the system is analyzed. Analysis results of the imaging system with different imaging modalities are obtained, which coincide with the ray tracing results. A demo test of the monochromatic imaging system was operated on the X-ray source, and the results are consonant with the simulation and the calculation. This diagnosis could have a broad prospect of application in the measurements on Shenguang laser facility. (authors)
Additional details
Publishing Information
- Journal Title
- High Power Laser and Particle Beams
- Journal Volume
- 25
- Journal Issue
- 3
- Journal Page Range
- p. 641-645
- ISSN
- 1001-4322
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 47083690
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CHINA; CRYSTALS; DESIGN; ICF DEVICES; IMAGES; LASERS; MONOCHROMATIC RADIATION; PERFORMANCE; PLASMA DIAGNOSTICS; SIMULATION; SPATIAL RESOLUTION; SPHERICAL CONFIGURATION; X RADIATION; X-RAY SOURCES
- Descriptors DEC
- ASIA; CONFIGURATION; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATION SOURCES; RADIATIONS; RESOLUTION; THERMONUCLEAR DEVICES
Optional Information
- Notes
- 6 figs., 2 tabs., 14 refs.