Ambient dose equivalent H*(d) - an appropriate philosophy for radiation monitoring onboard aircraft and in space?

  • 1. Atomic Institute of the Austrian Universities, Vienna (Austria)

Description

In this paper authors deals with the ambient dose equivalent H*(d) and their application for onboard Aircraft and Space station. The discussion and the carried out experiments demonstrated that the philosophy of H*(10) leads to an underestimation of the whole-body radiation exposure when applied onboard aircraft and in space. It therefore has to be considered to introduce a new concept that could be based on microdosimetric principles, offering the unique potential of a more direct correlation to radiobiological parameters

Files

36097704.pdf

Files (31.2 kB)

Name Size Download all
md5:c51acb061b774088dacfdee0f6e9295d
31.2 kB Preview Download

Additional details

Publishing Information

Publisher
Nuclear Regulatory Authority of the Slovak Republic
Imprint Place
Bratislava (Slovakia)
ISBN
80-88806-43-7
Imprint Title
IRPA Regional Congress on Radiation Protection in Central Europe
Imprint Pagination
573 p.
Journal Page Range
p. 1-4
Report number
INIS-SK--2005-030

Conference

Title
IRPA 2003
Dates
22-26 Sep 2003
Place
Bratislava (Slovakia)

Optional Information

Lead record
bzkbj-cty55
Notes
7 refs., 2 figs. Imprint:Also published on CD