Burn-up an important parameter during evaluation of the performance of any nuclear fuel. Among the various techniques available, the preferred one for its determination is based on accurate measurement of a suitable fission product monitor and the residual heavy elements. Since isotopes of rare earth elements are generally used as burn-up monitors, conditions were standardized for rapid separation (within 15 minutes) of light rare earths using high performance liquid chromatography based on either anion exchange (Partisil 10 SAX) in methanol-nitric acid medium or by cation exchange on a reverse phase column (Spherisorb 5-ODS-2 or Supelcosil LC-18) dynamically modified with 1-octane sulfonate or camphor-10-sulfonic acid (β). Both these methods were assessed for separation of individual fission product rare earths from their mixtures. A new approach has been examined in detail for rapid assay of neodymium, which appears promising for faster and accurate measurement of burn-up. (author)

Availability note (English)

Available from INIS in electronic form and/or on microfiche .

Files

29018465.pdf

Files (540.1 kB)

Name Size Download all
md5:67aad5d746320d486efeae55c8e13e0d
540.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
39 p.
Report number
IGC--184

Optional Information

Notes
16 refs., 12 figs., 4 tabs.