Published December 1, 2003 | Version v1
Journal article

Experience with the ZEUS central tracking detector

Description

The central tracking detector of the ZEUS experiment has been in operation since 1992. It is a cylindrical drift chamber, approximately 2 m in length and 1 m in diameter, and has operated reliably in a magnetic field of 1.43 T using a gas mixture of 83:12:5 argon/CO2/ethane with a trace (∼0.5%) of ethanol. Initial studies conducted between 1995 and 2000 using dE/dx to search for a long-term loss of gain were inconclusive. During the course of 2000, operational problems caused by repeated trips of high-voltage in the outer superlayers of the detector were experienced. These were attributed to the Malter effect, which has shown to be alleviated by the addition of water to the gas mixture. Consequently, a trace of water (∼0.15%) was added to the gas and has, to date, proved to be a successful remedy. Changes in the chamber performance due to the additional water are covered and solutions to the problems encountered are detailed

Additional details

Identifiers

DOI
10.1016/j.nima.2003.08.127;
PII
S0168900203024483;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
515
Journal Issue
1-2
Journal Page Range
p. 37-42
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
International workshop on aging phenomena in gaseous detectors
Dates
2-5 Oct 2001
Place
Hamburg (Germany)

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.