Published 2022 | Version v1
Journal article

Diagnostic performance of conventional magnetic resonance imaging for detection and grading of subscapularis tendon tear according to Yoo and Rhee classification system in patients underwent arthroscopic rotator cuff surgery

  • 1. Department of Radiology, Gil Medical Center, College of Medicine, Gachon University, Incheon (Korea, Republic of)
  • 2. Department of Radiology, Samsung Medical Center, College of Medicine, Sungkyunkwan University, 81 Irwon-Ro Gangnam-gu, 06351, Seoul (Korea, Republic of)
  • 3. Department of Orthopedic Surgery, Samsung Medical Center, College of Medicine, Sungkyunkwan University, Seoul (Korea, Republic of)

Description

To assess the diagnostic accuracy of conventional MRI for detecting and grading subscapularis (SSC) tears by applying the Yoo and Rhee classification. A total of 179 patients who underwent MRI followed by arthroscopic rotator cuff surgery were enrolled. Two musculoskeletal radiologists evaluated the SSC using axial, oblique sagittal, and oblique coronal MRI according to the Yoo and Rhee classification. Using arthroscopic findings as the reference standard, the sensitivity, specificity, accuracy, and interobserver agreement of SSC tears were analyzed. Arthroscopy confirmed that the numbers of type I, IIA, IIB, III, IV, and V tears were 35, 70, 35, 9, 9, and 0, respectively. The sensitivity, specificity, and accuracy of readers 1 and 2 for the detection of tears (type IIA or higher) were 85%, 75%, and 82%, and 89%, 70%, and 83%, respectively, while those for the detection of surgical candidates (type IIB or higher) were 77%, 75%, and 75%, and 77%, 83%, and 82%, respectively. The interobserver agreement for detecting SSC tear presence was substantial (κ = 0.70) for reader 1 vs. reader 2, and those for detecting the surgical candidate group was substantial (κ = 0.68) for reader 1 vs. reader 2. The interobserver agreement for grading SSC tears was excellent (κ = 0.86) for reader 1 vs. reader 2. Conventional MRI showed 82.5% and 78.5% average accuracy in detecting IIA and IIB or higher tears by applying the Yoo and Rhee classification for the diagnosis of SSC tears with an excellent interobserver agreement in tear grading.

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00256-021-03958-7

Additional details

Identifiers

Publishing Information

Journal Title
Skeletal Radiology
Journal Volume
51
Journal Issue
3
Journal Page Range
p. 659-668
ISSN
0364-2348
CODEN
SKRADI

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
53044801
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; ARMS; CLASSIFICATION; DIAGNOSIS; INJURIES; MUSCLES; NMR IMAGING; PERFORMANCE; SENSITIVITY; SPECIFICITY; SURGERY; TENDONS
Descriptors DEC
ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; DISEASES; LIMBS; MEDICINE