Quantitative assessment of the supraspinatus tendon on MRI using T2/T2* mapping and shear-wave ultrasound elastography: a pilot study
- 1. NYU Langone Medical Center/Hospital for Joint Diseases, Department of Radiology, New York, NY (United States)
- 2. NYU Langone Medical Center, Center for Biomedical Imaging, Department of Radiology, New York, NY (United States)
Description
To determine whether there is an association between T2/T2* mapping and supraspinatus tendon mechanical properties as assessed by shear-wave ultrasound elastography (SWE). This HIPAA-compliant prospective pilot study received approval from our hospital's institutional review board. Eight patients (3 males/5 females; age range 44-72 years) and nine shoulders underwent conventional shoulder MRI, T2/T2* mapping on a 3-T scanner, and SWE. Two musculoskeletal radiologists reviewed the MRI examinations in consensus for evidence of supraspinatus tendon pathology, with tear size measured for full-thickness tears. T2/T2* values and ultrasound shear-wave velocities (SWV) were calculated in three corresponding equidistant regions of interest (ROIs) within the insertional 1-2 cm of the supraspinatus tendon (medial, middle, lateral). Pearson correlation coefficients between T2/T2* values and SWV, as well as among T2, T2*, SWV and tear size, were calculated. There was a significant negative correlation between T2* and SWV in the lateral ROI (r = -0.86, p = 0.013) and overall mean ROI (r = -0.90, p = 0.006). There was significant positive correlation between T2 and measures of tear size in the lateral and mean ROIs (r range 0.71-0.77, p range 0.016-0.034). There was significant negative correlation between SWV and tear size in the middle and mean ROIs (r range -0.79-0.68, p range 0.011-0.046). Our pilot study demonstrated a potential relationship between T2* values and shear wave velocity values in the supraspinatus tendon, a finding that could lead to an improved, more quantitative evaluation of the rotator cuff tendons. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00256-016-2534-0Additional details
Identifiers
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 46
- Journal Issue
- 2
- Journal Page Range
- p. 191-199
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48019411
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BONE JOINTS; CORRELATIONS; DETECTION; ELASTICITY; FEASIBILITY STUDIES; IMAGE PROCESSING; MUSCLES; NMR IMAGING; RELAXATION TIME; RUPTURES; SPIN ECHO; TENDONS; ULTRASONOGRAPHY; VELOCITY; WAVE PROPAGATION; WEIGHTING FUNCTIONS
- Descriptors DEC
- ANIMAL TISSUES; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; FAILURES; FUNCTIONS; MECHANICAL PROPERTIES; ORGANS; PROCESSING; SKELETON