Published March 2016 | Version v1
Journal article

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • 1. Dept. of Radiation Oncology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

Description

In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median R2 of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer

Additional details

Publishing Information

Journal Title
Radiation Oncology Journal
Journal Volume
34
Journal Issue
1
Series
33 refs, 4 figs, 2 tabs
Journal Page Range
p. 64-75
ISSN
2234-1900

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
47086764
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTER CALCULATIONS; CORRELATIONS; FEASIBILITY STUDIES; IMAGES; LIVER; NMR IMAGING; RADIOTHERAPY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY