Measurement of the Portsmouth Gaseous Diffusion Plant criticality accident alarm

Description

The nuclear criticality accident radiation alarm system installed at the Portsmouth Gaseous Diffusion Plant was tested extensively at critical facilities located at the Los Alamos National Laboratory. The ability of the neutron scintillator radiation detection units to respond to a minimum accident of concern as defined in Standard ANSI/ANS-83.-1986 was demonstrated. Detector placement and the established trip point are based on shielding calculations performed by the Oak Ridge National Laboratory and criticality specialists at the Portsmouth plant. Based on these experiments and calculations, a detector trip point of 5 mrad/h in air is used. Any credible criticality accident is expected to produce neutron radiation fields >5 mrad/h in air at one or more radiation alarm locations. Each radiation alarm location has a cluster of three detectors that employs a two-out-of-three alarm logic. Earlier work focused on testing the alarm logic latching circuitry. This work was directed toward measurements involving the actual audible alarm signal delivered

Additional details

Publishing Information

Journal Title
Transactions of the American Nuclear Society
Journal Volume
63
Journal Page Range
p. 325-327.
ISSN
0003-018X
CODEN
TANSAO

Conference

Title
1991 Winter meeting of the American Nuclear Society (ANS) session on fundamentals of fusion reactor thermal hydraulics.
Dates
10-15 Nov 1991.
Place
San Francisco, CA (United States).

Optional Information

Secondary number(s)
CONF-911107--.