Reducing SS 304/316 hydrogen outgassing to 2x10-15 torr l/cm2 s

  • 1. Quantum Mechanics Corp., 21885 8th Street East, P.O. Box 1885, Sonoma, California 95476 (United States)

Description

Significant reduction in the outgassing rate of 300-series stainless steel is routinely attained through combination of electropolishing and vacuum baking. Preferential removal of Ni, Fe, and Mn from the surface of stainless steel by electropolishing creates a chromium-enriched surface. It also reduces the atomic surface area of the work piece closer to its geometric surface area. When the material is vacuum fired to remove interstitial hydrogen, the resultant stainless steel exhibits an outgassing rate of about 2x10-15 torr l/cm2 s, as well as drastically reduced adsorption, absorption, and catalytic behaviors

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Vacuum Science and Technology. A, International Journal Devoted to Vacuum, Surfaces, and Films
Journal Volume
25
Journal Issue
4
Journal Page Range
p. 1309-1311
ISSN
1553-1813

Optional Information

Notes
(c) 2007 American Vacuum Society