An analytic study on flooding heat transport limitation for a PFC two-phase closed thermosyphon
Description
The present study was conducted to determine flooding heat transfer limitation of a two-phase closed thermosyphon using PFC as working fluid. The variables such as pipe inner diameter, working fluid property, operating temperature were examined by way of analytic method. Comparison of experimental data on flooding heat transfer limitation shows a fairly good agreement with the analytic results. An expression for flooding maximum heat transfer rate was formulated as a function of Bond number and saturation pressure and written as follows ; Qmax = 0.989 · Ps0.286 · Bo1.74
Additional details
Publishing Information
- Publisher
- KSME
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the KSME 2000 fall annual meeting B
- Imprint Pagination
- 770 p.
- Journal Page Range
- p. 285-290
Conference
- Title
- KSME 2000 fall annual meeting B
- Dates
- 2-4 Nov 2000
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 36066945
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CONDENSATES; DRYOUT; EVAPORATORS; FLUID MECHANICS; HEAT TRANSFER; NUMERICAL ANALYSIS; PIPES; SATURATION; THERMOSYPHONS; TWO-PHASE FLOW
- Descriptors DEC
- ENERGY TRANSFER; FLUID FLOW; MATHEMATICS; MECHANICS; TUBES
Optional Information
- Notes
- 11 refs, 9 figs, 1 tab