Published 2000 | Version v1
Miscellaneous

An analytic study on flooding heat transport limitation for a PFC two-phase closed thermosyphon

  • 1. Sungkyunkwan Univ., Suwon (Korea, Republic of)

Description

The present study was conducted to determine flooding heat transfer limitation of a two-phase closed thermosyphon using PFC as working fluid. The variables such as pipe inner diameter, working fluid property, operating temperature were examined by way of analytic method. Comparison of experimental data on flooding heat transfer limitation shows a fairly good agreement with the analytic results. An expression for flooding maximum heat transfer rate was formulated as a function of Bond number and saturation pressure and written as follows ; Qmax = 0.989 · Ps0.286 · Bo1.74

Part of:
Proceedings of the KSME 2000 fall annual meeting B

Additional details

Publishing Information

Publisher
KSME
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the KSME 2000 fall annual meeting B
Imprint Pagination
770 p.
Journal Page Range
p. 285-290

Conference

Title
KSME 2000 fall annual meeting B
Dates
2-4 Nov 2000
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
36066945
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CONDENSATES; DRYOUT; EVAPORATORS; FLUID MECHANICS; HEAT TRANSFER; NUMERICAL ANALYSIS; PIPES; SATURATION; THERMOSYPHONS; TWO-PHASE FLOW
Descriptors DEC
ENERGY TRANSFER; FLUID FLOW; MATHEMATICS; MECHANICS; TUBES

Optional Information

Notes
11 refs, 9 figs, 1 tab