Description

First test results of temperature endurance tests are available on the development of materials to be used for permanent magnet flowmeters. Of the fully magnetized specimens only those examined at 6000 C furnace temperature exhibit a decrease in the field strength after 100 days already. For continuous examination of the performance of the neutron detector system a method based on noise analysis was developed which uses permanent reactivity modulation through the control system. This is to increase the reliability of detection of an incipient excursion. (orig.)

Abstract (German)

Zur Entwicklung von Werkstoffen fuer Dauermagnet-Durchflussmesser liegen erste Versuchsergebnisse von Temperatur-Dauerstandtests vor. Von den voll aufmagnetisierten Proben zeigen nur die bei 6000C Ofentemperatur untersuchten bereits nach 100 Tagen einen Abfall in der Feldstaerke. Fuer die kontinuierliche Ueberpruefung der Funktionsfaehigkeit der Neutronendetektoranlage wurde eine auf der Rauschanalyse basierende Methode entwickelt, die von einer dauernden Reaktivitaetsmodulation durch das Regelsystem Gebrauch macht. Hierdurch soll die Zuverlaessigkeit des Nachweises einer beginnenden Exkursion erhoeht werden. (orig.)

Additional details

Additional titles

Original title (German)
Entwicklung der Instrumentierung und Signalverarbeitung zur Kernueberwachung

Publishing Information

Imprint Title
Third quarterly report 1975
Imprint Pagination
vp.
Report number
KFK--1275/3

Optional Information

Notes
5 figs.; 1 tab.; 11 refs. Imprint:3. Vierteljahresbericht.
Secondary number(s)
EUR--5206 d.