Published October 31, 1978
| Version v1
Report
Restricted
Recalculation of loads on LOFT penetrations 1A, 2A, 3E, 3F, 5A, 5B, 5C, 5D, 5E, 5F, 7A, 9A, 11C, 17A, 17B, 20A, 20B, 20C, 21A
Description
The loads on the piping nozzles penetrating the LOFT containment vessel are presented. Since the design and construction of the containment vessel, piping systems that penetrate the nozzles have been changed. Consequently, the moments and forces on the containment vessel are different than those stated in LOFT specification S-1. Two combined load cases were tabulated, deadweight plus thermal expansion plus operating basis earthquake and deadweight plus safe shutdown earthquake
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A06/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 119 p.
- Report number
- LTR--1217-7
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10488190
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONFIGURATION; CONTAINMENT BUILDINGS; LOFT REACTOR; PIPES; SEISMIC EFFECTS; STRESS ANALYSIS; STRESSES
- Descriptors DEC
- CONTAINMENT; PWR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS