Published 2011 | Version v1
Journal article

WAZA-ARI: Computational dosimetry system for x-ray CT examinations. I. radiation transport calculation for organ and tissue doses evaluation using JM phantom

  • 1. Japan Atomic Energy Agency, 2-4 Shirakata, Tokai-mura, Ibaraki 319-1195 (Japan)
  • 2. Oita Prefecture-Mie Hospital, 3964-1 Miemachi-Miyano, Bungo-ono, Oita 879-7101 (Japan)
  • 3. Shin-Beppu Hospital, 3898 Tsurumi, Beppu, Oita 874-0833 (Japan)
  • 4. Tokai Univ. Oiso Hospital, 21-1 Gakkyou, Oiso-machi, Kanagawa 259-0198 (Japan)
  • 5. Tokai Univ. Hospital, 143 Shimokasuya, Isehara, Kanagawa 259-1193 (Japan)
  • 6. Oita Univ. of Nursing and Health Sciences, 2944-9 Megusuno, Oita, Oita 870-1201 (Japan)

Description

A web system of WAZA-ARI is being developed to assess radiation dose to a patient in a computed tomography examination. WAZA-ARI uses one of organ dose data sets corresponding to the options selected by a user to describe examination conditions. The organ dose data have been derived by the Particle and Heavy Ion Transport code system, combined with Japanese male (JM) phantom. The configuration of JM phantom is adjusted to the averaged JM adult. In addition, a new phantom is introduced by removing arms from JM phantom to take into account for dose calculations in torso examinations. Some of the organ doses by JM phantom without arms are compared with results obtained by using a MIRD-type phantom, which was applied in some previous dosimetry systems. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncr160

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
146
Journal Issue
1-3
Journal Page Range
p. 241-243
ISSN
0144-8420

Conference

Title
3. Asian and Oceanic Congress on Radiation Protection
Acronym
AOCRP-3
Dates
24-28 May 2010
Place
Tokyo (Japan)

Optional Information

Notes
12 refs