LOFT CIS Analysis Line 2 inches-IA-298-AB outside containment penetration S-2A
Description
Line 2''-IA-295-AB outside containment penetration S-2A was analyzed to ASME Section III, Subsection NC (Class 2) criteria. The line is part of the Containment Isolation System. The model considered the line from the penetration outward through the first isolation valve. Results of the analysis show that this section of the line meets Class 2 requirements without modification
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 52 p.
- Report number
- LTR--136-6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10470790
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONTAINMENT SYSTEMS; LOFT REACTOR; PIPES; STRESS ANALYSIS
- Descriptors DEC
- CONTAINMENT; PWR TYPE REACTORS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS