Measurement of the tandem mirror experiment x-ray spectrum

  • 1. Lawrence Livermore National Laboratory, Livermore, California 94550

Description

We measured x-ray spectrum at the Tandem Mirror Experiment (TMX) facility as a function of time using a new x-ray spectrometer with medium energy resolution that measures as well as identifies x rays in intense and varied particle and radiation backgrounds. The x-ray spectrum was deconvoluted from single-channel energy responses recorded one at a time for each shot. The data for each channel were normalized to the total x-ray energy, which was measured separately for each shot. After a few milliseconds during which conditions within the plasma pulse stabilized, the spectrum consisted of a broad peak with a typical median energy of 0.66 +- 0.04 keV, which can be interpreted as predominantly line emission. Resolution studies indicate that neonlike titanium may be a better interpretation than heliumlike oxygen; however, no quantitative model has been compared

Additional details

Publishing Information

Journal Title
J. Appl. Phys.
Journal Volume
53
Journal Issue
9
Series
J. Appl. Phys.
Journal Page Range
6085-6089
ISSN
0021-8979

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
14730160
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
ENERGY RESOLUTION; EXPERIMENTAL DATA; MAGNETIC MIRRORS; MATHEMATICAL MODELS; PLASMA; PULSES; STABILITY; TIME DEPENDENCE; TMX DEVICES; X-RAY SPECTRA
Descriptors DEC
DATA; INFORMATION; NUMERICAL DATA; OPEN PLASMA DEVICES; RESOLUTION; SPECTRA; THERMONUCLEAR DEVICES