Published 1994 | Version v1
Journal article

An infection of trans venous endocardial pacemaker electrodes diagnosed by gallium 67 imaging. A case report

  • 1. Hopital des Armees du Val-de-Grace, 75 - Paris (France)

Description

Authors report on a case of endo-carditis located on pacing atrial apparatus, 3 months after implantation, diagnosed by gallium 67 citrate whole-body scan. This non-conventional and non-invasive technique was tested 17 years ago. Because of numerous false-negative images and the development of echocardiography, the nuclear technique is not currently used to detect intracardiac infection. Based on different physical rules, scintigraphy is not limited by poor echo-genicity. Improvement of radionuclide techniques during the eighties and limitation of trans-thoracic echocardiography may leave an interesting place for infected focus intracardiac detection with the gallium 67 citrate imaging during a persistent unexplained fever. (authors). 18 refs., 2 figs

Additional details

Additional titles

Original title (French)
Endocardite sur sonde d'entrainement electrosystolique: apport de la scintigraphie au gallium. A propos d'un cas

Publishing Information

Journal Title
Medecine Nucleaire. Imagerie Fonctionelle et Metabolique
Journal Volume
8
Journal Issue
4
Journal Page Range
p. 193-196.
ISSN
0928-1258
CODEN
MNIMEX