Published 1984
| Version v1
Journal article
Chemical and physical parameters affecting the performance of the Os-191/Ir-191m generator
- 1. Harvard Medical School, Boston, MA
Description
The development of an Os-191/Ir-191m generator suitable for radionuclide angiography in humans has elicited much interest. This generator employs [OsO2Cl4]2- on AG MP-1 anion exchange resin with a Dowex-2 scavenger column and is elute with normal saline at pH 1. The parent Os species is, however, neither well-defined nor homogeneous leading to less than optimal breakthrough of Os-191 (5 x 10-3%) and modest Ir-191m yield (10-15%). The effect of a range of parameters on generator performance has been evaluated as has been the way in which the assembly and loading process affects generator performance. In addition, a number of potential alternative generator systems have been evaluated. 11 references, 2 figures, 8 tables
Additional details
Publishing Information
- Journal Title
- ACS Symp. Ser.
- Journal Issue
- no.241
- Series
- ACS Symp. Ser.
- ISSN
- 0097-6156
- CODEN
- ACSMC
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17068755
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- DIAGNOSTIC TECHNIQUES; IRIDIUM 191; OSMIUM 191; PERFORMANCE; PRODUCTION; RADIOISOTOPE GENERATORS; SPECIFICATIONS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; DAYS LIVING RADIOISOTOPES; EVEN-ODD NUCLEI; HEAVY NUCLEI; HOURS LIVING RADIOISOTOPES; INTERNAL CONVERSION RADIOISOTO; IRIDIUM ISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; NUCLEI; ODD-EVEN NUCLEI; OSMIUM ISOTOPES; RADIOISOTOPES; SECONDS LIVING RADIOISOTOPES; STABLE ISOTOPES