Published November 1980 | Version v1
Report Open

KENO-IV code benchmark calculation, (10)

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

Description

A series of benchmark tests has been undertaken in JAERI in order to examine the capability of JAERI's criticality safety evaluation system consisting of the Monte Carlo calculation code KENO-IV and the newly developed multi-group library MGCL. The present report describes the results of a benchmark test using criticality experiments at the Tank-type critical Assembly (TCA) of JAERI. In all, 125 cases of experiments have been calculated for H2O moderated square lattice of UO2 or UO2 + PuO2 mixed oxide fuel rods with varying lattice configurations. For all the 125 cases, the effective multiplication factor (k sub(eff)) can be predicted as 0.995 +- 0.004 by this calculational method. Particularly for the 26 cases dealing with neutron absorbers, the k sub(eff) can be predicted as 0.998 +- 0.003, which is very accurate calculation compared with other cases. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

12629745.pdf

Files (1.8 MB)

Name Size Download all
md5:9703323743f52e37fe45b1b52bf898d1
1.8 MB Preview Download

Additional details

Additional titles

Subtitle (English)
A light water reactor critical assembly

Publishing Information

Imprint Pagination
50 p.
Report number
JAERI-M--9147