Published October 2016 | Version v1
Journal article

Optimum Insulation Thickness for Walls and Roofs for Reducing Peak Cooling Loads in Residential Buildings in Lahore

  • 1. University of Engineering and Technology, Lahore (Pakistan). Dept. of Architectural Engineering and Design
  • 2. Institute of Business Management, Karachi (Pakistan). Dept. of Computer Science

Description

Thermal insulation is the most effective energy saving measure for cooling in buildings. Therefore, the main subject of many engineering investigations is the selection and determination of the optimum insulation thickness. In the present study, the optimum insulation thickness on external walls and roofs is determined based on the peak cooling loads for an existing residential building in Lahore, Pakistan. Autodesk at the rate Revit 2013 is used for the analysis of the building and determination of the peak cooling loads. The analysis shows that the optimum insulation thickness to reduce peak cooling loads up to 40.1 percent is 1 inch for external walls and roof respectively. (author)

Additional details

Publishing Information

Journal Title
Mehran University Research Journal of Engineering and Technology
Journal Volume
35
Journal Issue
4
Journal Page Range
p. 523-532
ISSN
0254-7821

INIS

Country of Publication
Pakistan
Country of Input or Organization
Pakistan
INIS RN
47121537
Subject category
S42: ENGINEERING;
Descriptors DEI
ACOUSTIC INSULATION; BUILDING MATERIALS; COMPUTER CALCULATIONS; COMPUTER NETWORKS; COOLING LOAD; ENERGY SOURCES; HEAT TRANSFER; THICKNESS; WALLS
Descriptors DEC
DIMENSIONS; ENERGY TRANSFER; MATERIALS