Published May 2000
| Version v1
Miscellaneous
An application of adjoint sensitivity method for the evaluation of sensitivity parameters of a point kinetics model
Description
Adjoint Sensitivity Method was applied to a Point Kinetics Model to predict the change in system responses of peak power value and its time location due to the change in system parameters. In an ASM, the variation of system response was expressed as a simple algebraic integral form containing a base case, error distribution of system parameters and adjoint function. Adjoint function was obtained from the system adjoint to forward system. In this paper the change in system response caused by perturbed initial condition was calculated. The variation in peak power was calculated in good agreement with the direct simulation result
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS spring meeting
- Imprint Pagination
- [CDROM]
- Journal Page Range
- [15 p.]
Conference
- Title
- 2000 spring meeting of the KNS
- Dates
- 26-27 May 2000
- Place
- Kori (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 34027519
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPUTER CALCULATIONS; ERRORS; PERTURBATION THEORY; REACTOR KINETICS; SENSITIVITY; SIMULATION
- Descriptors DEC
- KINETICS
Optional Information
- Notes
- 5 refs, 3 figs, 1 tab