Published February 1986
| Version v1
Journal article
Time resolved neutron spectrum measurements at the mirror fusion test facility
Creators
- 1. Univ. of California, Lawrence Livermore National Lab., P.O. Box 808, L-405, Livermore, CA 94550
Description
An advanced neutron diagnostic system has been developed for spectrum measurements on MFTF. Its collimated field of view allows spatially resolved neutron spectrum measurements. The 10 Mhz pulse height analysis and particle identification capability allow spectrum measurements in intervals as short as 10 ms. These capabilities will be used for space and time resolved determinations of ion energy from measurements of neutron Doppler width
Additional details
Publishing Information
- Journal Title
- IEEE Trans. Nucl. Sci.
- Journal Volume
- NS-33
- Journal Issue
- 1
- Series
- IEEE Trans. Nucl. Sci.
- Journal Page Range
- vp.
- ISSN
- 0018-9499
- CODEN
- IETNA
Conference
- Title
- IEEE nuclear science symposium.
- Dates
- 23-25 Oct 1985.
- Place
- San Francisco, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 17079912
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOPPLER EFFECT; IONS; MFTF DEVICES; MHZ RANGE 01-100; NEUTRON DETECTION; NEUTRON SPECTRA; PARTICLE IDENTIFICATION; PERFORMANCE; PLASMA DIAGNOSTICS; PULSES; RADIATION DETECTORS; SPATIAL RESOLUTION; SPECIFICATIONS; TIME RESOLUTION
- Descriptors DEC
- CHARGED PARTICLES; DETECTION; FREQUENCY RANGE; MAGNETIC MIRRORS; MEASURING INSTRUMENTS; MHZ RANGE; OPEN PLASMA DEVICES; RADIATION DETECTION; RESOLUTION; SPECTRA; THERMONUCLEAR DEVICES; TIMING PROPERTIES
Optional Information
- Secondary number(s)
- CONF-851009--.