BrachyView: verification of LDR patient plans – hardware optimisation
Creators
- 1. Centre for Medical Radiation Physics, University of Wollongong, North Wollongong, NSW (Australia)
- 2. St George Cancer Care Centre, St George Hospital, Kogarah, NSW (Australia)
- 3. Advanced Computer System Pty Ltd, Rome (Italy)
Description
BrachyView is a novel in-body imaging system developed with the objective to provide real-time intraoperative dosimetry for low dose rate (LDR) prostate brachytherapy treatments. Seed positions can be reconstructed after implantation by the means of a high resolution pinhole gamma camera. The obtained dataset is then combined with conventional trans-rectal ultrasound (TRUS) imaging to locate the effective source position within the prostate volume. This study presents a comparison of two data sets containing 96 and 98 I-125 brachytherapy sources and readout by two different pin-hole collimators with 800 µm and 500 µm, respectively. This study aims to assess the effect on reconstruction of large pinholes which allow for large Field of View (FoV) and statistics of counts on the seed's projections. It was found that 100% of seeds were reconstructed by the means of the 500 µm collimator. Results from the 800 µm data showed that only 70% of seeds were reconstructed with a total 3D discrepancy of 8.20 mm in respect to CT data and an increased reconstructed position inaccuracy.
Availability note (English)
Available online as open access from https://doi.org/10.1088/1742-6596/1154/1/012005; also from https://iopscience.iop.org/issue/1742-6596/1154/1Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Physics. Conference Series (Online)
- Journal Volume
- 1154
- Journal Issue
- 2019
- Journal Page Range
- 6 p.
- ISSN
- 1742-6596
Conference
- Title
- Mini-Micro-Nano-Dosimetry and Innovative Technologies in Radiation Oncology Workshops
- Acronym
- MMND-ITRO 2018
- Dates
- 6-11 Feb 2018
- Place
- Mooloolaba, QLD (Australia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- Australia
- INIS RN
- 52095918
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; BEAM OPTICS; BRACHYTHERAPY; COMPARATIVE EVALUATIONS; DOSIMETRY; GAMMA CAMERAS; IMAGES; IODINE 125; LOW DOSE IRRADIATION; NEOPLASMS; PATIENTS; POSITION SENSITIVE DETECTORS; PROSTATE; RADIATION SOURCE IMPLANTS; REAL TIME SYSTEMS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BODY; CAMERAS; DAYS LIVING RADIOISOTOPES; DISEASES; ELECTRON CAPTURE RADIOISOTOPES; EVALUATION; GLANDS; IMPLANTS; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IODINE ISOTOPES; IRRADIATION; ISOTOPES; MALE GENITALS; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIATION DETECTORS; RADIATION SOURCES; RADIOISOTOPES; RADIOLOGY; RADIOTHERAPY; THERAPY
Optional Information
- Notes
- 2 figs., 1 tab., 9 refs.