Direct 4D PET MLEM reconstruction of parametric images using the simplified reference tissue model with the basis function method for [11C]raclopride
Creators
- 1. Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal (Canada)
Description
This work assesses the one-step late maximum likelihood expectation maximization (OSL-MLEM) 4D PET reconstruction algorithm for direct estimation of parametric images from raw PET data when using the simplified reference tissue model with the basis function method (SRTM-BFM) for the kinetic analysis. To date, the OSL-MLEM method has been evaluated using kinetic models based on two-tissue compartments with an irreversible component. We extend the evaluation of this method for two-tissue compartments with a reversible component, using SRTM-BFM on simulated 3D + time data sets (with use of [11C]raclopride time-activity curves from real data) and on real data sets acquired with the high resolution research tomograph. The performance of the proposed method is evaluated by comparing voxel-level binding potential (BPND) estimates with those obtained from conventional post-reconstruction kinetic parameter estimation. For the commonly chosen number of iterations used in practice, our results show that for the 3D + time simulation, the direct method delivers results with lower %RMSE at the normal count level (decreases of 9–10 percentage points, corresponding to a 38–44% reduction), and also at low count levels (decreases of 17–21 percentage points, corresponding to a 26–36% reduction). As for the real 3D data set, the results obtained follow a similar trend, with the direct reconstruction method offering a 21% decrease in %CV compared to the post reconstruction method at low count levels. Thus, based on the results presented herein, using the SRTM-BFM kinetic model in conjunction with the OSL-MLEM direct 4D PET MLEM reconstruction method offers an improvement in performance when compared to conventional post reconstruction methods. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/60/11/4533Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 60
- Journal Issue
- 11
- Journal Page Range
- p. 4533-4549
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47072530
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; ANIMAL TISSUES; CARBON 11; IMAGE PROCESSING; IMAGES; MAXIMUM-LIKELIHOOD FIT; POSITRON COMPUTED TOMOGRAPHY; SIMULATION
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BODY; CARBON ISOTOPES; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; EVEN-ODD NUCLEI; ISOTOPES; LIGHT NUCLEI; MATHEMATICAL LOGIC; MATHEMATICAL SOLUTIONS; MINUTES LIVING RADIOISOTOPES; NUCLEI; NUMERICAL SOLUTION; PROCESSING; RADIOISOTOPES; TOMOGRAPHY