Ropes eye plaque brachytherapy dosimetry for two models of 103Pd seeds
Creators
- 1. Islamic Azad University, Research and Science Branch, Tehran, Iran (Iran, Islamic Republic of). Dept. of Nuclear Engineering
- 2. Nuclear Science and Technology Research Institute, Tehran, Iran (Iran, Islamic Republic of). Agricultural, Medical and Industrial Research School
- 3. Tehran University of Medical Sciences, Faculty of Medicine, Tehran, Iran (Iran, Islamic Republic of). Dept. of Biophysics
- 4. Talca University, Talca, Chile (Chile). Faculty of Engineering
Description
Full text: Brachytherapy dose distributions are calculated for I5mm ROPES eye plaque loaded with model Theragenics200 and IR06-103Pd seeds. The effects of stainless steel backing and Acrylic insert on dose distribution along the central axis of the eye plaque and at critical ocular structure are investigated. Monte Carlo simulation was carried out with the Version 5 of the MCNP. The dose at critical ocular structure by considering the eye composition was calculated. Results are compared with the calculated data for CaMS eye plaque loaded with Theragenics200 palladium-103 seeds and model 6711 iodine-125 seed. The air kerma strength of the IR06- 103Pd seed to deliver 85 Gy in apex of tumor in water medium was calculated to be 4.10 U/seed. Along the central axis of stainless steel plaque loaded with new 103Pd seeds in Acrylic insert, the dose reduction relative to water is 6.9% at 5 mm (apex). Removal of the Acrylic insert from the plaque (replacing with water) did not make significantly difference in dose reduction results (O.2%). The presence of the stainless steel backing results in dose enhancement near the plaque relative to water. Doses at points of interest are higher for ROPES eye plaque when compared to CaMS eye plaque. The dosimetric parameters calculated in this work for the new palladium seed, showed that in dosimetry point of view, the IR06-103Pd seed is suitable for use in brachytherapy. The effect of Acrylic insert on dose distribution is negligible and the main effect on dose reduction is due to the presence of stainless steel plaque backing. (author)
Availability note (English)
Available in abstract form only, full text entered in this recordAdditional details
Publishing Information
- Journal Title
- Australasian Physical and Engineering Sciences in Medicine
- Journal Volume
- 34
- Journal Issue
- 2
- Journal Page Range
- p. 223-231
- ISSN
- 0158-9938
- CODEN
- AUPMDI
INIS
- Country of Publication
- Australia
- Country of Input or Organization
- Australia
- INIS RN
- 43108955
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRACHYTHERAPY; CALCULATION METHODS; DOSIMETRY; EYES; MONTE CARLO METHOD; NUCLEAR MEDICINE; PLAQUE FORMATION; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOTHERAPY
- Descriptors DEC
- BODY; CALCULATION METHODS; DOSES; FACE; HEAD; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RADIOTHERAPY; SENSE ORGANS; THERAPY
Optional Information
- Notes
- 37 refs., 05 figs., 04 tabs.