Published November 1980 | Version v1
Report Open

Test of high temperature fuel element, (3)

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

Description

Electrical heaters simulating the VHTR fuel rods were fabricated to use in the High Temperature Fuel Test Section. The heat transfer surfaces of these heaters are made of graphite. These heaters were tested in the condition of 10000C and 40 bar helium gas flow and the maximum heat rate of 300 W/cm was obtained. The measured heat transfer coefficients were in good agreement with the established experimental correlations. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

12629919.pdf

Files (1.3 MB)

Name Size Download all
md5:89b932572afc2d83a782ded219bb61b3
1.3 MB Preview Download

Additional details

Additional titles

Subtitle (English)
Development of graphite heaters

Publishing Information

Imprint Pagination
41 p.
Report number
JAERI-M--9196