Published April 1991 | Version v1
Report Restricted

Demonstration tests of the high temperature wide range neutron monitoring system in the AVR

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Reactor Instrumentation Lab.

Description

A High Temperature Wide Range Neutron Monitoring System (HWNMS) was developed for HTGRs by JAERI. The special features of the HWNMS are as follows. The neutron sensor can be installed inside the pressure vessel of the HTGR. The maximum operating temperature of the neutron sensor is 800deg C. The HWNMS is designed to have low electric noises. The HWNMS provides the neutron flux monitoring and a reactor period indication from source range to power range. The HWNMS is designed to satisfy the requirements for the Post-Accident Monitor (PAM) of the HTGR. The performance test of the HWNMS was carried out in the research reactor JRR-4. The demonstration test was also performed in the actual high temperature gas-cooled reactor AVR. (orig./HP)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
42 p.
Report number
Juel--2468