Published October 1986
| Version v1
Journal article
Efficient, economical production of oxygen-15 labeled tracers with low energy
- 1. Computer Technology and Imaging, Inc., Berkeley, CA (USA)
- 2. California Univ., Los Angeles (USA). School of Medicine
- 3. TRIUMF, Vancouver, British Columbia (Canada)
Description
An investigation of optimum target design and accelerator beam conditions for the efficient, low cost production of oxygen-15 (batch and continuous flow modes) for O-15 labelled tracers in PET studies has been pursued. (author)
Additional details
Publishing Information
- Journal Title
- J. Labelled Compd. Radiopharm.
- Journal Volume
- 23
- Journal Issue
- 10-12
- Series
- J. Labelled Compd. Radiopharm.
- Journal Page Range
- 1214-1216
- ISSN
- 0362-4803
- CODEN
- JLCRD
Conference
- Title
- 6. international symposium on radiopharmaceutical chemistry.
- Dates
- 29 Jun - 3 Jul 1986.
- Place
- Boston, MA (USA).
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 18082001
- Subject category
- S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ISOTOPE PRODUCTION; OXYGEN 15; POSITRON COMPUTED TOMOGRAPHY; RADIOPHARMACEUTICALS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; COMPUTERIZED TOMOGRAPHY; DRUGS; EMISSION COMPUTED TOMOGRAPHY; EVEN-ODD NUCLEI; ISOTOPES; LABELLED COMPOUNDS; LIGHT NUCLEI; MATERIALS; MINUTES LIVING RADIOISOTOPES; NUCLEI; OXYGEN ISOTOPES; RADIOACTIVE MATERIALS; RADIOISOTOPES; TOMOGRAPHY