Cost and effectiveness of radon-resistant features in new school buildings

  • 1. Environmental Protection Agency, Research Triangle Park, NC (United States). Air and Energy Engineering Research Lab.
  • 2. Infiltec, Falls Church, VA (United States)

Description

Recent concerns over elevated levels of radon in existing buildings have prompted the design and construction of a number of school buildings that either are radon resistant or incorporate features that facilitate post-construction mitigation if needed. This paper described initial results of a study of several schools with radon-resistant features that were recently constructed in the northeastern U.S. These designs are generally based on experience with radon mitigation in existing houses and schools and radon-resistant new house construction. The study was limited to slab-on-grade schools, where the most common radon-resistant school design is active subslab depressurization (ASD). The additional construction costs for eight schools built with ASD ranged from $3 to $11 per square meter of slab area. The radon contractors who designed these systems have tended to overdesign the radon-reduction systems in the absence of specific written guidance to follow to lessen potential liability in the event of system failure. Design features include detailed sealing of all slab cracks, multiple exhaust stacks, and extensive subslab piping

Additional details

Publishing Information

Publisher
American Society of Heating Refrigeration and Air Cond.
Imprint Place
Atlanta, GA (United States)
ISBN
0-919110-83-2
Imprint Title
Healthy buildings
Imprint Pagination
412 p.
Journal Page Range
p. 236-240.

Conference

Title
healthy buildings.
Acronym
IAQ '91
Dates
4-8 Sep 1991.
Place
Washington, DC (United States).

Optional Information

Secondary number(s)
CONF-910979--.