Published August 2009 | Version v1
Miscellaneous

Repair and preventive maintenance technology for BWR reactor internals and piping

  • 1. Toshiba Corp., Tokyo (Japan)
  • 2. Hitachi-GE Nuclear Energy, Hitachi, Ibaraki (Japan)
  • 3. Tokyo Electric Power Co., Inc., Tokyo (Japan)

Description

Stress corrosion cracking of welding portion has found in many domestic and foreign BWR reactor internals and Primary Loop Recirculation piping. Also, repair and preventive maintenance technologies for SCC has been developed and/or adopted to BWRs in recent years. This paper introduces the sample of these technologies, such as seal-welding for SCC on BWR reactor internals, preventive maintenance technology for PLR piping such as Corrosion Resistant Cladding, Internal Polishing and Induction Heating Stress Improvement. These technologies are introduced on 'E-Journal of Advanced Maintenance', which is an international journal on a exclusive website of Japan Society of Maintenology. (author)

Part of:
Proceedings of the 6th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-6-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 6th annual meeting of Japan Society of Maintenology
Imprint Pagination
601 p.
Journal Page Range
p. 187-190

Conference

Title
6. annual meeting of Japan Society of Maintenology
Dates
3-5 Aug 2009
Place
Sapporo, Hokkaido (Japan)

Optional Information

Notes
9 refs., 12 figs. Imprint:Nippon hozen gakkai dai-6-kai gakujutsu koenkai yoshishu