Published March 2004 | Version v1
Journal article

A sample preparation method of individual aerosol particles in SPM analysis

  • 1. Chinese Academy of Sciences, Shanghai (China). Shanghai Inst. of Applied Physics

Description

A new method for sample preparation of individual aerosol particle in SPM analysis was developed. Aerosol particles were collected directly on the polyvinyl butyral (PVB) foil by using air sampler. Microscopic observation indicates that the particles were separated completely and the interval of particles was reasonable. The SPM experiment proves that PVB foils have excellent stability under proton microbeam bombardment and are a suitable backing material for supporting the single particle for SPM analysis. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
27
Journal Issue
3
Journal Page Range
p. 185-187
ISSN
0253-3219

Optional Information

Notes
4 figs., 1 tab., 7 refs.