There is a newer version of the record available.

Published November 2019 | Version v1
Journal article

Repeatability and reproducibility of measurements of low dissolved radiocesium concentrations in freshwater using different pre-concentration methods

  • 1. National Institutes for Quantum and Radiological Science and Technology (Japan)
  • 2. National Institute of Advanced Industrial Science and Technology (Japan)
  • 3. Fukushima Branch Office QST, c/o FMU, National Institutes for Quantum and Radiological Science and Technology (Japan)
  • 4. Kyushu Environmental Evaluation Association (Japan)
  • 5. Japan Environment Science Co.,Ltd. (Japan)
  • 6. Environmental Control Center Co.,Ltd. (Japan)
  • 7. IDEA Consultants, Inc. (Japan)
  • 8. Tokyo Power Technology Ltd. (Japan)
  • 9. Kindai University, Department of Biotechnology and Chemistry, Faculty of Engineering (Japan)
  • 10. Nippon Chemical Environment Center Co.,Ltd. (Japan)
  • 11. National Agriculture and Food Research Organization, Institute for Rural Engineering (Japan)
  • 12. Chugai Technos Corporation (Japan)
  • 13. Japan Chemical Analysis Center (Japan)
  • 14. Kankyo Bunseki Kenkyusho Co.,Ltd. (Japan)
  • 15. Suncoh Environmental Research Center Co.,Ltd. (Japan)
  • 16. The University of Tokyo, Atmosphere and Ocean Research Institute (Japan)
  • 17. University of Tsukuba, Center for Research in Isotopes and Environmental Dynamics (Japan)
  • 18. Japan Atomic Energy Agency (Japan)
  • 19. Fukushima Prefectural Centre for Environmental Creation (Japan)
  • 20. KANSO CO.,LTD. (Japan)

Description

We assessed the repeatability and reproducibility of methods for determining low dissolved radiocesium concentrations in freshwater in Fukushima. Twenty-one laboratories pre-concentrated three of 10 L samples by five different pre-concentration methods (Prussian-blue-impregnated filter cartridges, coprecipitation with ammonium phosphomolybdate, evaporation, solid-phase extraction disks, and ion-exchange resin columns), and activity of radiocesium was measured. The z-scores for all of the 137Cs results were within ± 2, indicating that the methods were a good degree of precision. The relative standard deviations (RSDs) indicating the reproducibility among different laboratories were larger than the RSDs indicating the repeatability in each separate laboratory.

Additional details

Identifiers

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
322
Journal Issue
2
Journal Page Range
p. 477-485
ISSN
0236-5731
CODEN
JRNCDM

Optional Information

Copyright
Copyright (c) 2019 The Author(s)