Published 1996 | Version v1
Book

Accumulated dose calculations in Indian PHWRs under DBA

  • 1. Nuclear Power Corporation of India Ltd., Mumbai (India). Reactor Safety Analysis Group

Description

Accumulated gamma dose inside reactor building due to release of fission products from equilibrium core of Indian PHWR under accident condition has been assessed. The assessment has been done for the radiation tolerance limit of the critical equipment inside reactor building. The basic source data has been generated using computer code ORIGEN2 written and developed by Oak Ridge National Laboratory, USA (ORNL). This paper discusses the details of the calculations done on the basis of certain assumption which are mentioned at relevant places. The results indicate accumulated gamma dose at a few typical locations inside reactor building under accident condition. (author). 1 ref., 1 tab., 1 fig

Part of:
National conference on radiation shielding and protection (RASP-96): Proceedings

Additional details

Publishing Information

Publisher
Allied Publishers Limited.
Imprint Place
New Delhi (India)
ISBN
81-7023-541-3
Imprint Title
National conference on radiation shielding and protection (RASP-96): Proceedings
Imprint Pagination
321 p.
Journal Page Range
p. 245-248.

Conference

Title
national conference on radiation shielding and protection.
Acronym
RASP-96
Dates
26-28 Jun 1996.
Place
Kalpakkam (India).

Optional Information