Addressing the dose perturbation of metallic implant in spinal Stereotactic Body Radiotherapy (SBRT)

  • 1. Department of Biomedical Physics, Faculty of Medicine, Nguyen Tat Thanh University, Ho Chi Minh City, 755414 (Viet Nam)
  • 2. Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur, 50603 (Malaysia)

Description

This study compares methods of addressing the dose perturbation occurred in planning and delivery stage of spinal adjuvant Stereotactic Body Radiotherapy (SBRT) caused by the presence of titanium implants. Dose prediction by TPS was conducted while the CT number of titanium was (a) default, calculated by AAA algorithm ("No Overridden"); (b) relative electron density, mass density matched, calculated by AAA algorithm ("AAA"); (c) relative electron density, mass density matched, calculated by AXB algorithm ("AXB"). In (i) phantom study, dose predictions were compared with measurement conducted with 2 mm, 6 mm and 10 mm thickness of titanium alloy Grade 5 (Ti6Al4V) using field sizes of 1 × 1 cm2, 2 × 2 cm2, and 4 × 4 cm2. In (ii) planning study, retrospective dose predictions on patient plans were carried out to evaluate the impact on clinical outcome. The mean discrepancies (%) between measurement and "No Overridden", "AAA", "AXB" at tissue - titanium interface (titanium - tissue interface) were respectively -16.86 (10.93), -14.05 (11.24), 0.71 (1.54) for 2 mm and 6 mm thickness of titanium; and -18.42 (11.20), -18.29 (11.04), -10.14 (0.01) for 10 mm thickness of titanium, respectively. The patient study results by "AXB" yielded a significant deficit in tumour volume coverage at prescribed dose compared to "AAA" and "No Overridden" by 5.23 % and 9.06 %, respectively. "No Overridden" and "AAA" can potentially generate acceptable prediction in specific scenarios where the depth of target remains approximately unchanged while the gantry rotates. The AXB algorithm is recommended to be used in routine practice involving titanium implants. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/1248/1/012040

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
1248
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1742-6596

Conference

Title
18. Asia-Oceania Congress of Medical Physics (AOCMP); 16. South-East Asia Congress of Medical Physics (SEACOMP)
Dates
11-14 Nov 2018
Place
Kuala Lumpur (Malaysia)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
53055904
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALGORITHMS; COMPUTERIZED TOMOGRAPHY; DENSITY; ELECTRON DENSITY; IMPLANTS; NEOPLASMS; PHANTOMS; RADIATION DOSES; RADIOTHERAPY; TITANIUM; TITANIUM ALLOYS
Descriptors DEC
ALLOYS; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; ELEMENTS; MATHEMATICAL LOGIC; MEDICINE; METALS; MOCKUP; NUCLEAR MEDICINE; PHYSICAL PROPERTIES; RADIOLOGY; STRUCTURAL MODELS; THERAPY; TOMOGRAPHY; TRANSITION ELEMENT ALLOYS; TRANSITION ELEMENTS