Published March 2003 | Version v1
Journal article

A case study on the decommissioning of TRIGA II type research reactor

  • 1. Radioactive Waste Management and Nuclear Facility Decommissioning Technology Center, Tokyo (Japan)

Description

As one example of decommissioning studies of low power research reactors, RANDEC studied the decommissioning case of a 100kW TRIGA II type research reactor. Immediate dismantling (one year after shutdown) and deferred dismantling after several safestore terms were selected as decommissioning modes, and decommissioning schedules, dismantling methods, costs etc. were studied for these selected modes. The following results were obtained; - generated radwaste exceeding clearance level was approx. 87tons in the case of immediate dismantling, and approx. 27 tons in the case of deferred dismantling after a 50-year-safestore. - as the index of 100 for dismantling costs of the reactor without dismantling of the concrete biological shielding, the estimated index is 1,090 (except the reactor building dismantling) in the immediate dismantling mode. For the deferred dismantling modes after a 5-year, 10-year, 20-year, and a 50-year-safestore, the indexes are 1,300, 1,500, 1,700, and 2,300 respectively. As described above, the decommissioning cost was estimated that the longer safestore resulted in the cost increase, because more management costs were needed for the care during the longer safestore. (author)

Additional details

Publishing Information

Journal Title
Dekomisshoningu Giho
Journal Issue
no.27
Journal Page Range
p. 28-49
ISSN
1343-3881

Optional Information

Notes
22 figs., 5 tabs.