Published March 1986 | Version v1
Journal article

Effect of interpolation error in pre-processing codes on calculations of self-shielding factors and their temperature derivatives

  • 1. Reactor Research Centre, Kalpakkam (India). Fast Breeder Test Reactor Design Group
  • 2. International Atomic Energy Agency, Vienna (Austria). International Nuclear Data Committee

Description

We investigate the effect of interpolation error in the pre-processing codes LINEAR, RECENT and SIGMA1 on calculations of self-shielding factors and their temperature derivatives. We consider the 2.0347 to 3.3546 keV energy region for 238U capture, which is the NEACRP benchmark exercise on unresolved parameters. The calculated values of temperature derivatives of self-shielding factors are significantly affected by interpolation error. The sources of problems in both evaluated data and codes are identified and eliminated in the 1985 version of these codes. This paper helps to (1) inform code users to use only 1985 versions of LINEAR, RECENT, and SIGMA1 and (2) inform designers of other code systems where they may have problems and what to do to eliminate their problems. (author)

Additional details

Publishing Information

Journal Title
Radiat. Eff.
Journal Volume
96
Journal Issue
1-4
Series
Radiat. Eff.
Journal Page Range
235-238
ISSN
0033-7579
CODEN
RAEFB

Conference

Title
international conference.
Acronym
Nuclear data for basic and applied science
Dates
13-17 May 1985.
Place
Santa Fe, NM (USA).