Published September 1994 | Version v1
Journal article

Reflux condenser mode with non-condensible gas: assessment of Cathare against Bethsy test 7.2C

  • 1. CEA-CENG-DRN/DTP/STR, 17, rue des Martyrs, 38054, Grenoble Cedex 9 (France)

Description

The condensation process in steam generator (SG) U-tubes with the presence of non-condensible gas (nitrogen) has been investigated on the Bethsy integral test facility. Bethsy test 7.2c, dealing with the reflux condenser mode, consists of a succession of steady states where the effects of the amount of nitrogen, core power and secondary pressure on the primary-to-secondary heat transfer have been analysed. Examination of the non-condensible gas distribution in the SG U-tubes leads to the identification of an active zone where condensation takes place and a passive zone with a high concentration of nitrogen where no heat transfer occurs. The experimental data serve as a basis for safety code assessment. The first verification of these situations has been performed with the Cathare code, and results are presented and discussed in the following. ((orig.))

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
149
Journal Issue
1-3
Journal Page Range
p. 291-298.
ISSN
0029-5493
CODEN
NEDEAU

Conference

Title
6. international topical meeting on nuclear reactor thermal hydraulics (Nureth-6).
Dates
5-8 Oct 1993.
Place
Grenoble (France).