An integrated CMOS 0.15 ns digital timing generator for TDC's and clock distribution systems
Description
This paper describes the architecture and performance of a new high resolution timing generator used as a building block for time to Digital Converters (TDC) and clock alignment functions. The timing generator is implemented as an array of locked loops. This architecture enables a timing generator with sub-gate delay resolution to be implemented in a standard digital CMOS process. The TDC function is implemented by storing the state of the timing generator signals in an asynchronous pipeline buffer when a hit signal is asserted. The clock alignment function is obtained by selecting one of the timing generator signals as an output clock. The proposed timing-generator has been mapped into a 1.0 microm CMOS process a RMS error of the time taps of 48 ps has been measured with a bin size 0.15 ns. Used as a TDC device a RMS error of -6 ps has been obtained. A short overview of the basic principles of major TDC and timing generator architectures is given to compare the merits of the proposed scheme to other alternatives
Additional details
Publishing Information
- Journal Title
- IEEE Transactions on Nuclear Science
- Journal Volume
- 42
- Journal Issue
- 4Pt1
- Journal Page Range
- p. 753-757.
- ISSN
- 0018-9499
- CODEN
- IETNAE
Conference
- Title
- medical imaging conference.
- Acronym
- Nuclear science symposium
- Dates
- 30 Oct - 5 Nov 1994.
- Place
- Norfolk, VA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 27015991
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DESIGN; DRIFT CHAMBERS; HIGH ENERGY PHYSICS; PARTICLE IDENTIFICATION; PERFORMANCE; RADIATION DETECTORS; TIME RESOLUTION; TIMING CIRCUITS; TIMING PROPERTIES
- Descriptors DEC
- ELECTRONIC CIRCUITS; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBERS; PHYSICS; PROPORTIONAL COUNTERS; RESOLUTION
Optional Information
- Secondary number(s)
- CONF-941061--.