RBE variation between fast neutron beams as a function of energy. Intercomparison involving 7 neutron therapy facilities

  • 1. Universite Catholique de Louvain (UCL), Louvain-la-Neuve (Belgium)
  • 2. Ghent Rijksuniversiteit (Belgium)
  • 3. King Faisal Specialist and Research Centre, Riyadh, Saudi Arabica (Saudi Arabia)
  • 4. National Accelerator Centre, Faure (South Africa)
  • 5. Harper Hospital Detroit, MI, (United States)
  • 6. Centre Hospitalier Regional, 45 - Orleans (France)
  • 7. Centre de Lutte Contre le Cancer Antoine Lacassagne, 06 - Nice (France)

Description

In fast neutron therapy, the relative biological effectiveness (RBE) of a given beam varies to a large extent with the neutron energy spectrum. This spectrum depends primarily on the energy of the incident particles and on the nuclear reaction used for neutron production. However, it also depends on other factors which are specific to the local facility, e.g., target, collimation system, etc. Therefore direct radiobiological intercomparisons are justified. The present paper reports the results of an intercomparison performed at seven neutron therapy centres: Orleans, France (p(34)+Be), Riyadh, Saudi Arabia (p(26+Be), Ghent, Belgium (d(14.5)+Be), Faure, South Africa (p(66+Be), Detroit, USA (d(48)+Be), Nice, France (p(65)+Be) and Louvain-la-Neuve, Belgium (p(65)+Be). The selected radiobiological system was intestinal crypt regeneration in mice after single fraction irradiation. The observed RBE values (ref cobalt-60 γ-rays) were 1.79±0.10, 1.84±0.07, 2.24±0.11, 1.55±0.044, 1.51±0.03, 1.50± and 1.52±0.004, respectively. When machine availability permitted, additional factors were studied: two vs one fraction (Ghent, Louvain-la-Neuve), dose rate (Detroit), influence of depth in phantom (Faure, Detroit, Nice, Louvain-la Neuve). In addition, at Orleans and Ghent, RBEs were also determined for LD50 at 6 days after selective abdominal irradiation and were found to be equal to the RBEs for crypt regeneration. The radiological intercomparisons were always combined with direct dosimetric intercomparisons and, when possible in some centres, with microdosimetric investigations. (author)

Additional details

Additional titles

Original title (French)
Variation de l'EBR entre les faisceaux de neutrons rapides selon l'energie. Intercomparaison realisee aupres de 7 centres de neutrontherapie

Publishing Information

Journal Title
Bulletin du Cancer. Radiotherapie
Journal Volume
83
Series
21 refs.
Journal Page Range
p. 55-63.
ISSN
0924-4212
CODEN
BCRAEE

Conference

Title
Meeting of the European heavy particle therapy group.
Dates
4-6 May 1995.
Place
Orleans (France).