Interference between PET and MRI sub-systems in a silicon-photomultiplier-based PET/MRI system
Creators
- 1. Kobe City College of Technology, Kobe (Japan)
- 2. Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine, Osaka (Japan)
- 3. Neomax Engineering, Takasaki (Japan)
- 4. Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine, Osaka (Japan)
Description
The silicon-photomultiplier (Si-PM) is a promising photodetector, especially for integrated PET/MRI systems, due to its small size, high gain, and low sensitivity to static magnetic fields. The major problem using a Si-PM-based PET system within the MRI system is the interference between the PET and MRI units. We measured the interference by combining a Si-PM-based PET system with a permanent-magnet MRI system. When the RF signal-induced pulse height exceeded the lower energy threshold level of the PET system, interference between the Si-PM-based PET system and MRI system was detected. The prompt as well as the delayed coincidence count rates of the Si-PM-based PET system increased significantly. These noise counts produced severe artifacts on the reconstructed images of the Si-PM-based PET system. In terms of the effect of the Si-PM-based PET system on the MRI system, although no susceptibility artifact was observed on the MR images, electronic noise from the PET detector ring was detected by the RF coil and reduced the signal-to-noise ratio (S/N) of the MR images. The S/N degradation of the MR images was reduced when the distance between the RF coil and the Si-PM-based PET system was increased. We conclude that reducing the interference between the PET and MRI systems is essential for achieving the optimum performance of integrated Si-PM PET/MRI systems.
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/56/13/026Additional details
Identifiers
- DOI
- 10.1088/0031-9155/56/13/026;
- PII
- S0031-9155(11)82373-0;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 56
- Journal Issue
- 13
- Journal Page Range
- p. 4147-4159
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 43022753
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- IMAGES; INTERFERENCE; MAGNETIC FIELDS; NMR IMAGING; PERMANENT MAGNETS; POSITRON COMPUTED TOMOGRAPHY; PULSES; SENSITIVITY; SIGNALS; SIGNAL-TO-NOISE RATIO; SILICON
- Descriptors DEC
- COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; ELEMENTS; EMISSION COMPUTED TOMOGRAPHY; EQUIPMENT; MAGNETS; SEMIMETALS; TOMOGRAPHY