SU-F-J-95: Impact of Shape Complexity On the Accuracy of Gradient-Based PET Volume Delineation
Creators
- 1. University of North Carolina, Chapel Hill, NC (United States)
- 2. MIM Software Inc., Cleveland, OH (United States)
Description
Purpose: Explore correlation of tumor complexity shape with PET target volume accuracy when delineated with gradient-based segmentation tool. Methods: A total of 24 clinically realistic digital PET Monte Carlo (MC) phantoms of NSCLC were used in the study. The phantom simulated 29 thoracic lesions (lung primary and mediastinal lymph nodes) of varying size, shape, location, and 18F-FDG activity. A program was developed to calculate a curvature vector along the outline and the standard deviation of this vector was used as a metric to quantify a shape's "complexity score". This complexity score was calculated for standard geometric shapes and MC-generated target volumes in PET phantom images. All lesions were contoured using a commercially available gradient-based segmentation tool and the differences in volume from the MC-generated volumes were calculated as the measure of the accuracy of segmentation. Results: The average absolute percent difference in volumes between the MC-volumes and gradient-based volumes was 11% (0.4%–48.4%). The complexity score showed strong correlation with standard geometric shapes. However, no relationship was found between the complexity score and the accuracy of segmentation by gradient-based tool on MC simulated tumors (R2 = 0.156). When the lesions were grouped into primary lung lesions and mediastinal/mediastinal adjacent lesions, the average absolute percent difference in volumes were 6% and 29%, respectively. The former group is more isolated and the latter is more surround by tissues with relatively high SUV background. Conclusion: The complexity shape of NSCLC lesions has little effect on the accuracy of the gradient-based segmentation method and thus is not a good predictor of uncertainty in target volume delineation. Location of lesion within a relatively high SUV background may play a more significant role in the accuracy of gradient-based segmentation.
Additional details
Identifiers
- DOI
- 10.1118/1.4956003;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 43
- Journal Issue
- 6
- Journal Page Range
- vp.
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48082940
- Subject category
- S60: APPLIED LIFE SCIENCES; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ACCURACY; CORRELATIONS; FLUORINE 18; FLUORODEOXYGLUCOSE; IMAGES; LUNGS; LYMPH; LYMPH NODES; MONTE CARLO METHOD; NEOPLASMS; PHANTOMS; POSITRON COMPUTED TOMOGRAPHY; SIMULATION
- Descriptors DEC
- ANTIMETABOLITES; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BIOLOGICAL MATERIALS; BODY; BODY FLUIDS; CALCULATION METHODS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; FLUORINE ISOTOPES; HOURS LIVING RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LIGHT NUCLEI; LYMPHATIC SYSTEM; MATERIALS; MOCKUP; NANOSECONDS LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; ORGANS; RADIOISOTOPES; RESPIRATORY SYSTEM; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- (c) 2016 American Association of Physicists in Medicine